Fail Safe

Redundant System

Service and Diagnostic Software

Unique service and diagnostic software for high level maintenance

High Extinguishing Efficiency

Utilizes dry powder to suppress all classes of fires and prevent re ignition

Reliable

Low risk of false alarms

Easy Installation

Durable, flexible stainless steel tubing can be routed to monitor long distances or tight spaces

Cost Effective

Cost effective

Fail Safe

Redundant System

Service and Diagnostic Software

Unique service and diagnostic software for high level maintenance

High Extinguishing Efficiency

Utilizes dry powder to suppress all classes of fires and prevent re ignition

Reliable

Low risk of false alarms

Easy Installation

Durable, flexible stainless steel tubing can be routed to monitor long distances or tight spaces

Cost Effective

Cost effective

BUSShield

The potential for disastrous human loss is present in most fire events. In public transportation vehicles such as busses it could be catastrophic.Apart from arson, there are a few common reasons for the ignition of buses or coaches amongst them extreme heat, vehicle vibration, material fatigue or malfunction, fuel / hydraulic fluids leakage or electric short circuit as well as inadequate maintenance.
Many bus fire events originate in either the engine or battery compartments, which are usually out of the driver’s sight. It is therefore difficult for the driver to notice a fire if it occurs which might result in a slow response time increasing both life loss and damage risk.
Lehavot developed BusShield by leveraging its experience as a primary supplier for all of the in-service military Mine Resistant Ambush Protected (MRAP) vehicles developed to counter the IED threat over the last ten years. Amongst other innovations, this work saw the company develop an advanced Fast Release Valve able to rapidly counter blossoming explosions and keep military operators safe.
As well as compliance with UNECE R107, Lehavot and BusShield are certified to ISO 9001:2008, as well as FM Approved and proudly P-Mark badged. The Delta detectors are additionally rated to MIL-STD 810, 461 and 1275.

bus fire protection system r107 approved

System Structure

bus fire protection system r107 approved
bus fire protection system r107 approved

Control Panel

Located in the operator’s dashboard panel.
Visible and audible alert with manual activation.

Power: Green |  Fire: Red | Fault: Yellow

bus fire protection system r107 approved

Dry Chemical Agent Cylinders

ABC 94 top fire rate extinguishing media Agent Cylinders, with capacities of 8 kg. Pressurized with dry nitrogen at a pressure of 25 bars at 21°C. Designed to work at temperatures from -40°C to 60°C. The discharge valve MIL-spec is pyrotechnically activated.

Linear Heat Detector

Linear Heat Detector is a continuous heat detector capable of detecting heat anywhere along its length. The simply installed detector is highly reliable and offers excellent performance.

Features and Benefits

Certified

Events

BUSWORLD 5.7.03.2020
ISTANBUL TURKEY
hALL 10 STAND 02
15-20 June 2020
Hannover Germany
Hall 12 Booth e 21/1

Contact us